Buy ASTM E Standard Test Method for Water in Organic Liquids by Coulometric Karl Fischer Titration from SAI Global. Find the most up-to-date version of ASTM E at Engineering WATER IN LIQUIDS BY KARL FISCHER. This test method covers the determination of water from 0 to % mass in most liquid organic chemicals, with Karl.

Author: Gazilkree Ball
Country: Brunei Darussalam
Language: English (Spanish)
Genre: Career
Published (Last): 20 April 2014
Pages: 118
PDF File Size: 9.37 Mb
ePub File Size: 4.15 Mb
ISBN: 257-4-87021-839-8
Downloads: 62313
Price: Free* [*Free Regsitration Required]
Uploader: Akinoramar

Automated solutions from Metrohm for the determination of TAN and TBN as well as water content according to Karl Fischer make sure that results are always in time with the customers — even when the workload is several thousand samples per day. In lubricating oils, near-infrared spectroscopy NIRS is a viable tool for analyzing the content of aromatics, nitrogen and oil, and polycyclic aromatic asm PAHs.

The hydroxyl number HN indicates the amount of KOH in mg corresponding to the hydroxyl groups in 1 g sample. Tests to establish analyser or system performance can be a cost effective move. Enkeltparameter axtm til spildevand og andre vandtyper.

Hydroxyl value in lubricants. Electrode Finder Sample preparation Titrotherm. Aquamax KF Coulometric Coulometric titration system for water in oil. Valgmuligheder Ti-Touch Kompakt, stand-alone, let anvendelig potentiometrisk titrator til brug ved rutinetitreringer.

Vi bruger cookies Vores website bruger cookies for at give dig den bedst mulige browseroplevelse. This Aquamax KF is fully portable with a patented automatic compensated errors technique and results manager software. Lubricant reliability relies on fast, precise and accurate analysis that complies with international standards.

  GIRLOSOPHY A SOUL SURVIVAL KIT PDF

Applikationsnyheder, praktiske tips til laboratoriet og mere. The Aquamax KF portable has been designed for applications where water in oil measurements need to be performed outside the laboratory.

Like the raw material, these products are also susceptible to oxidation. Since the sample itself does not come into contact with the KF reagent, interfering side reactions and matrix effects can be excluded.

Vi genopfinder volumetrisk Karl Fischer-titrering: Ny titreringsplatform til det moderne laboratorium: Tanker drivers, process or instrument engineers can perform quick and accurate measurements to quantify water content that conform to the following standards: A portable moisture meter for use outside the laboratory.

A range of analysers is available for short term hire or long term lease. Training We offer a variety of on-site and off-site courses to educate, and ensure good practice. Manual for Aquamax KF Portable. Vores website bruger cookies for at give dig den bedst mulige browseroplevelse. The additives in lubricants can react with KF reagents and falsify the result.

Related items DC Water in oil monitor, by-pass system. Further parameters are distillation analysis, flash point, pour point as well as density and viscosity.

Lubricating oil, crude oil, solvents Lubricating oil, petroleum products Insulating oil liquid. Equipment Rental A range of analysers is available for short term hire or long term lease.

Stand-alone titratorer til coulometriske vandindhold: It is a straightforward and precise parameter to monitor degradation processes. Request a quote Download a datasheet Share this page Share.

Lubricant analysis according to international standards | Metrohm

Amongst others, they reduce friction, transfer heat, transmit power, protect against wear, and astn corrosion. The method is a major benefit for laboratories that have to analyze a great number of samples per day.

  DECRETO 71-86 PDF

We offer a variety of on-site and off-site courses to educate, and ensure good practice. Overview Specification More Data. The method requires no boiling under reflux or other sample preparation steps. Industrial lubricants have a lot of crucial functions. Login Metrohm Agencies Denmark: Aquamax KF Portable designed for portable use optional carry case complies with many international standards.

ASTM E1064 – 16

Easily biodegradable lubricants can also be manufactured from natural fats and oils. Valgmuligheder Titrino plus Alsidig potentiometrisk, stand-alone titrator til standard rutineapplikationer.

Coulometric titration system for water in oil. In ester-based lubricants, the HN indicates the degree of esterification. Simple to use coulometic titrator for water in oil.

Water in oil monitor, by-pass system. The correct heating temperature lies below the ast, temperature of the sample and is determined in preliminary tests.

ASTM E1064

Water content of oil samples. Tanker drivers, e10064 or instrument engineers can perform quick and accurate measurements to quantify water content that conform to the following standards:.

Datasheet for Aquamax KF Portable. In a KF drying oven, a stream of dry carrier gas transfers the expelled water into the titration cell. A portable system for non-chemists.